A robust collection of applications to improve workflow and boost diagnostic power.
The DV24.0 Continuum* Pak offers the latest advanced applications to supplement your Discovery* MR750 and MR750w and Optima* MR450w system to help you utilize the full potential of MR imaging.
3D PROMO: provides 3D volumetric imaging correction of motion in real-time through a unique, state-of-the-art algorithm that reduces the need for retakes during neuro exams.
FOCUS: delivers a highly efficient method for increasing the resolution in Single Shot DW EPI sequences. Utilizing a multi-dimensional selective excitation, FOCUS supports zoomed, small field of view imaging of specific organs with higher diagnostic quality, lower artifacts and faster exam times compared to conventional diffusion imaging.
Enriched Diffusion Imaging: GE Healthcare's Real Time Field Adjustment (RTFA) technology corrects field imperfections that result in image distortions and loss of resolution in diffusion imaging techniques. RTFA enables large field of view coverage in the body, shorter echo times and increased SNR compared with previous techniques.
BrainWave 3.0: a new, simplified solution for functional MRI with support for multi-design paradigms, event-related activity and extensions for diffusion tractography and report generation support.
Body Navigators: designed to allow for free breathing, motion-controlled acquisitions. DWI, MRCP, T2 and T1 high-resolution images are scanned without a breath hold, and routine liver imaging is performed in less than 15 minutes.
Black Blood Single Shot Fast Spin Echo: Utilizing single shot acquisitions allows large volume multi-slice coverage for morphological imaging of the heart and vessels. That means Black Blood SSFSE improves patient comfort by reducing the number of breath holds, as well as reducing overall scan times.
PS-MDE: Phase Sensitive Inversion Recovery is used to reduce the sensitivity of inversion delay times for enhanced cardiac exams. The result is consistent imaging without worrying about the delay time.
eSWAN 2.0: a high-resolution 3D multi-echo gradient echo sequence that results in an SNR that is higher than a single echo acquisition. SWAN 2.0 generates magnitude and phase images from a single acquisition, allowing you to differentiate between microvasculature bleeds and calcified lesions.
Images courtesy of:
Centre Hospitalier Laennec - Creil France, Hospital St Joseph - Paris France, Centre Cardiologique Du Nord - Paris France, Seirei Hamamatsu Hospital - Shizuoka Japan, Mount Sinai Medical Center - New York, NY USA, MVZ Radiologie & Nuklearmedizin - Furth, Germany, Hull Royal Infirmary - Hull, United Kingdom, Morriston Hospital - Morriston, United Kingdom, Centro Cardiologico - Monzino, Italy, Hospital For Special Surgery - New York, NY USA