Body

Abdomen Pelvis

Fast body imaging with 4 volumes
120kV / 280mA / 0.5 sec rotation / BMI 29 / 10mSv

Tri-phase Liver

Whole organ dynamic imaging – tri-phase liver
100kV / 350mA / 0.4 sec rotation / BMI 23 / 3.3mSv/phase


Aorta

Fast body vascular imaging with 3 volumes
120kV / 310mA / 0.5 sec rotation  / BMI 29


Cardiac

Comprehensive Cardiac

1-beat comprehensive cardiac assessment – even at high heart rates
120kV / 510mA / 0.28 sec rotation / BMI 32 / 86 bpm / 8mSv


Cardiac low dose

1-beat, high definition, motion free, low dose cardiac
80kV / 500mA / 0.28 sec rotation / BMI 23 / 55 bpm / 0.9mSv


Cardiac low dose

1-beat, high definition, motion free, low dose cardiac
80kV / 350mA / 0.28 sec rotation / BMI 21 / 69 bpm / 0.6mSv


Cardiac Rest/Stress Perfusion

Rest/Stress perfusion with motion free coronaries
120kV / 325 mA / 0.28 sec rotation / 60bpm / 77bpm /BMI 28


Cardiovascular

Whole Aorta

Fast body vascular imaging using 4 volumes
120kV / 415mA / 0.4 sec rotation / BMI 29 / 12mSv


Coverage

Whole organ coverage
80kV / 450 mA / 0.28 sec rotation / BMI 23 / 2.1mSv


Whole Aorta

Fast body angio imaging with 4 volumes
120kV / 350mA / 0.28 sec rotation / BMI 29 


Triple Rule Out

Low kV gated chest CT angiography
80kV / 450mA / 0.28 sec rotation / BMI 23 / bpm 56-59 

TAVI Follow – Up Whole Aorta

Rapid TAVR planning (follow up) with 4 volumes
120kV / 480mA / 0.28 sec rotation


Musculoskeletal

Musculoskeletal

High definition MSK imaging with screw: 1 volume
120kV / 200mA / 0.5 sec rotation

High definition MSK imaging with screw: 1 volume
140kV / 120mA / 0.5 sec rotation

 

High definition MSK imaging with screw: 1 volume
120kV / 220 mA / 0.5 sec rotation

Neurology

Carotids

High definition head neck angio with 2 volumes

100kV / 300mA / 0.8 sec rotation / BMI 25 / 2.3mSv



Routine Brain

Excellent IQ in the Posterior Fossa and Bone/Brain Interface

Axial / 100kV / 1 sec rotation / CTDIvol 40.9mGy

Whole Brain Perfusion with Head/Neck CTA

Perfusion: 80kV / 14cm coverage / ASiR-V 80% / 1.2mSv

Helical / 0.5 sec rotation / 120kV / 1.66mSv



Routine Brain in One Rotation

Remarkable gray-white matter differentiation

Axial / 100kV / 1 sec rotation / CTDIvol 41.1mGy



LCD – Low Noise

Excellent low contrast detectability with low noise

140kV / 345mA / 0.8 sec rotation / 4.2mSv

Whole Brain Perfusion and Dynamic 4D CTA

Whole brain perfusion with variable sampling (2s/20+5s/30)

80kV / 150mA / 1 sec rotation / 3.6mSv



Neuro Imaging

Routine head imaging

140kV / 250mA / 1 sec rotation / 1.9mSv



Circle of Willis

Low dose high definition neuro CT angiography

120kV / 200mA / 0.8 sec rotation



GSI Xtream

Monochromatic 70 keV

Kidney Stone Composition

Pulmonary Embolism

Gout Visualization

70 keV with Iodine map

Spine